Relay Interface Analog to Digital Status Input Support Contact Us EECI Home Page View Cart

Ethernet Digital to Analog (1 and 2 channel)
DAC1-16ENET Digital to Analog Converter (16 bit, 1 channel)
DAC2-16ENET Digital to Analog Converter (16 bit, 2 channel)

Ethernet Digital to Analog (1 and 2 channel, 16 bit)

USB WiFi Ethernet RS-232 RS-485

Click the add button to add items, then click BUY

DAC1-16ENET D to A (16 Bit).$ 119.95 Quantity    

DAC2-16ENET D to A (16 Bit).$ 139.95 Quantity    

ACCESSORIES
CC-RJ6 RJ-45 Patch Cable......$ 7.95 Quantity    

PS-5VDC-1000 Wall Adapter.....$ 12.95 Quantity    



8 Channel Version

EN-D Enclosure for the DAC2-ENET

Additional Accessories


WiFi Digital to Analog with Relay Control DAC2-16WIFI shown with the
EX-8M and RN-8 Relay Card






Typical usage include control and deployment with equipment, devices and infrastructure in the following applications:   Water/fluid/air valve position control, variable-frequency drive (VFD) motor control, 4-20ma loop control, environmental controls (such as to control temperature, air flow, air damper position, water flow in zone valve systems, etc.), RF radio and instrument control (such as to control gain, voltage, current, etc.), telescope directional position control, antenna directional position control, to control satellite dish azimuth and elevation, light level control (such as to control laser, IR, ambient, etc.), audio sound level control, motion control, speed control, thrust level, thrust vector control, power output, solenoid position control, use in test fixtures (such as to control voltage, current, resistance, etc.), use in solar array applications (such as to control panel azimuth and elevation, power and charging functions, etc.) and hundreds of other applications.
  • Connects directly to Ethernet, allowing direct Ethernet control of Digital to Analog output levels (and direct Ethernet control of relays with optional expansion module)
  • Connects to any available RJ-45 on your network
  • Heartbeat signal technology provides alarm if unit is tampered with or is damaged
  • 1 channel of 16 bit Digital to Analog (65,536 increments in output level) with DAC1-16ENET
  • 2 channels of 16 bit Digital to Analog (65,536 increments in output level) with DAC2-16ENET
  • Selectable reference voltage - allows for 0 to 3.3v, 0 to 5v or user supplied voltage output ranges
  • Available with high precision voltage reference pre-installed. Allows for (0 to 1.2v), (0 to 2.048v), (0 to 2.5v), (0 to 3v) or (0 to 4.096v) output ranges - Contact EECI support for more info
  • Add the CO-420T 4-20mA Transmitter for Ethernet controlled 4-20mA current loop transmitter
  • Full technical support provided by on staff advisors
  • Expandable to monitor up to 8 digital inputs or control up to 8 relays using the EX-8M expansion card or...
  • Expandable to control up to 128 relays, monitor 128 inputs (or combinations of relays and inputs) using EXM-16 or EXM-32 Relay I/O Expansion Modules
  • Expandable to also monitor Analog to Digital channels or control additional Digital to Analog levels - contact EECI support for more info
  • Compatible with Windows 11, Windows 10, Windows Server, Windows 8.1, Windows 7, Windows Vista and Windows XP
  • No complicated communication protocol - just one line of code is required to control all analog levels (or control all relays) to greatly simplify software development. The Ethernet connection and all initialization is completely automated.
  • Use your own program to control, read and process the analog output levels for any application or use the included software
  • Source code examples included on CD in Microsoft Visual Basic.Net, Visual C#, C++, Python and others
  • LabVIEW compatible, includes LabVIEW VI, graphic software example and DLL library
  • Includes CD (or optional USB Flash Drive) with Data Logging Software, device driver and user interface. Requires power adapter (PS-5VDC-1000) and Ethernet RJ-45 patch cable (CC-RJ6)

DAC2-ENET Description and Spec

DAC2-ENET Tech Reference

View All


Electronic Energy Control, Inc.
14960 Maple Ridge Rd
Milford Center OH 43045-9016

TOLL FREE (24 hour order line)
(800) 842-7714

Technical Support (937) 349-6000
Internet Email cst@eeci.com

Copyright ©1996 - 2025 Electronic Energy Control, Inc.
All Rights Reserved
Document End